1.1 | 1.1 Scope | 0 |
1.2 | 1.2 Application: AS/NZS 3000 plus this Standard, with distributor and regulator requirements checked first | 0 |
1.3-1.5 | 1.3 Referenced documents, 1.4 Definitions, 1.5 Symbols | 0 |
2.1.1-2.1.2 | 2.1.1 Scope of Section and 2.1.2 Rating classifications | 0 |
2.1.3 | 2.1.3 Selection of generating set rating from load characteristics | 1 |
2.1.4 | 2.1.4 Same system of supply whatever the source | 0 |
2.10 | 2.10 Lightning protection of generating set installations | 0 |
2.11-2.12 | 2.11 Sets as normal supply to a main switchboard and 2.12 sets connected as an alternative supply | 0 |
2.2 | 2.2 Location of generating sets: exhaust, weather, hazardous areas and fuel fire risk | 1 |
2.3.1 | 2.3.1 Protection from mechanical damage | 0 |
2.3.2 | 2.3.2 Protection from moving parts | 0 |
2.3.3 | 2.3.3 Protection against thermal effects above 120 C | 0 |
2.3.4 | 2.3.4 Protection against fuel leakage | 1 |
2.4.1 | 2.4.1 Control of the generating set | 1 |
2.4.2 | 2.4.2 Prime mover isolating device to prevent starting during work | 1 |
2.4.2.1 | 2.4.2.1 Operation of the prime mover isolating device | 0 |
2.4.2.2 | 2.4.2.2 Location and securing of the isolating device | 0 |
2.4.3 | 2.4.3 Synchronization with the network or other sets | 1 |
2.4.4 | 2.4.4 Starting batteries and battery charging | 1 |
2.5(a)-(c) | 2.5 Earthing arrangements (a) to (c): one MEN connection at the main switchboard | 0 |
2.5(d)-(e) | 2.5 Earthing arrangements (d) and (e): no parallel neutral and earth; no electrode at the set | 0 |
2.5(f)-(g) | 2.5 Earthing arrangements (f) and (g): changeover preserves installation functions; NZ main switchboard connection | 0 |
2.6.1.1 | 2.6.1.1 Installation to AS/NZS 3000 and generator switchboards for multiple sets | 0 |
2.6.1.2 | 2.6.1.2 Isolation from the normal supply system and approval for parallel running | 1 |
2.6.1.3 | 2.6.1.3 Generator neutral treated as a live conductor | 0 |
2.6.2 | 2.6.2 Overcurrent protection of outgoing circuits from the set | 1 |
2.6.3 | 2.6.3 Generator output isolator switching all live conductors | 0 |
2.7.1 | 2.7.1 Changeover devices for alternative (standby) supply and back-feed prevention | 1 |
2.7.10 | 2.7.10 Changeover switching in the generator neutral (Australia and New Zealand rules) | 1 |
2.7.11-2.7.13 | 2.7.11 to 2.7.13 Three-pole and four-pole changeover arrangements | 0 |
2.7.2 | 2.7.2 Operation of changeover devices: break before make, active and neutral switching, no earth switching | 1 |
2.7.3 | 2.7.3 Mechanical interlocking of changeover devices | 1 |
2.7.4 | 2.7.4 Changeover device with intermediate off position used as a main switch | 1 |
2.7.5 | 2.7.5 Changeover device without an off position: permitted connection points | 0 |
2.7.6 | 2.7.6 Changeover device voltage, current and fault ratings | 1 |
2.7.7-2.7.8 | 2.7.7 Access and 2.7.8 identification of changeover devices | 1 |
2.7.9 | 2.7.9 Automatic changeover back to normal supply and ATS used as a main switch | 1 |
2.8 | 2.8 Earthing and bonding of the generating set | 0 |
2.9 | 2.9 Generator switchboards and switchgear | 0 |
3.1 | 3.1 General: Section 3 applies to permanently connected sets | 0 |
3.2-access | 3.2 Location: barriers against unauthorised access, access space and exits | 1 |
3.2-environment | 3.2 Location: ventilation and lighting of generator rooms | 1 |
3.3 | 3.3 Guarding of live parts | 0 |
3.4 | 3.4 Transformers | 0 |
3.5-changeover | 3.5 Sets supplying safety and essential services: changeover time and grouped switchgear | 1 |
3.5-loads | 3.5 Sets supplying safety and essential services: selective protection, no unintended paralleling, other loads | 1 |
3.5-supply | 3.5 Sets supplying safety and essential services: capability, fuel, fire resistance and dedication | 1 |
4.1 | 4.1 General: sets connected by detachable connections | 0 |
4.2-other | 4.2.3 and 4.2.7 Other connection requirements for detachable connections | 0 |
4.2.4 | 4.2.4 Current limiting of each incoming generator supply | 0 |
4.2.5 | 4.2.5 Enclosure of live parts at the inlet and neutral pin isolation | 0 |
4.2.6 | 4.2.6 Marking of generator inlet fittings | 0 |
4.3 | 4.3 Earthing and bonding of sets on detachable connections; no separate electrode | 0 |
4.4 | 4.4 Connection of a portable set to a dedicated wiring system (New Zealand only) | 0 |
AppA-C | Appendices A to C | 0 |
AppD | Appendix D: Construction and performance of self-contained transportable sets up to 25 kW | 0 |
intro | Status of AS/NZS 3010:2017 + A1 | 0 |