NZISM-1 | NZISM Governance, Documentation, and Classification System | 94 |
NZISM-2 | Certification and Accreditation (C&A) for Government Systems | 25 |
NZISM-3 | Personnel Security, Physical Security, and Cryptography | 114 |
NZISM-4 | Access Control, Authentication, and Communications Security | 0 |
NZISM-5 | Network Security, System Hardening, and Application Security | 57 |
NZISM-6 | Event Logging, Monitoring, Incident Response, and Business Continuity | 0 |
NZISM-7 | Media Handling, Outsourcing, Cloud Services, and Remote Access | 0 |
NZISM-8 | Security Risk Management, Vulnerability Management, and Incident Reporting | 0 |
1.1-COMPLIANCE | Compliance language, baseline and good-practice controls, waivers and exceptions (1.1) | 0 |
1.1.64.C.01 | 1.1.64.C.01 Dispensations for baseline non-compliance granted by Accreditation Authority | 0 |
1.1.65.C.01 | 1.1.65.C.01 Risk assessment supporting a non-compliance dispensation | 1 |
1.1.66.C.01 | 1.1.66.C.01 Consult originating agency before classification non-compliance | 0 |
1.1.66.C.02 | 1.1.66.C.02 Consult foreign government before NZISM non-compliance | 0 |
1.1.67.C.01 | 1.1.67.C.01 Formal consultation for shared and All-of-Government systems | 0 |
1.1.68.C.01 | 1.1.68.C.01 Annual review of non-compliance decisions | 0 |
1.1.69.C.01 | 1.1.69.C.01 Retain records of non-compliance decisions and assessments | 0 |
1.1.69.C.02 | 1.1.69.C.02 Recording residual risk from unimplemented recommended controls | 1 |
1.2-AUTHORITY | Applicability and authority: who must comply and on what mandate (1.2) | 0 |
1.2.15.C.01 | 1.2.15.C.01 Use current NZISM version for system design | 0 |
1.2.15.C.02 | 1.2.15.C.02 Comply with GCSB-designated priority NZISM requirements | 0 |
10.1.42.C.01 | 10.1.42.C.01 Fibre optic backbone at CONFIDENTIAL and above | 0 |
10.1.42.C.02 | 10.1.42.C.02 Fibre optic cable preferred for backbone infrastructure | 0 |
10.1.43.C.01 | 10.1.43.C.01 Use fibre optic cabling generally | 0 |
10.1.43.C.02 | 10.1.43.C.02 Consult GCSB on fibre with conductive strengtheners | 0 |
10.1.43.C.03 | 10.1.43.C.03 Consult GCSB when copper cables are specified | 0 |
10.1.43.C.04 | 10.1.43.C.04 Avoid fibre with conductive metal strengtheners or sheaths | 0 |
10.1.44.C.01 | 10.1.44.C.01 Cabling installed to New Zealand standards | 0 |
10.1.45.C.01 | 10.1.45.C.01 Cable and conduit colours by classification | 1 |
10.1.45.C.02 | 10.1.45.C.02 Label and document additional colour-coded networks | 1 |
10.1.46.C.01 | 10.1.46.C.01 Agree foreign system cable colour at TOP SECRET | 0 |
10.1.46.C.02 | 10.1.46.C.02 Foreign system cable colours distinct at TOP SECRET | 0 |
10.1.46.C.03 | 10.1.46.C.03 Agree foreign system cable colour with stakeholders | 0 |
10.1.46.C.04 | 10.1.46.C.04 Avoid shared colours for foreign and New Zealand cables | 0 |
10.1.47.C.01 | 10.1.47.C.01 Seek GCSB advice on combining special network cabling | 0 |
10.1.47.C.02 | 10.1.47.C.02 Only approved fibre groupings in shared conduits | 1 |
10.1.48.C.01 | 10.1.48.C.01 Fibres within one cable sheath carry one classification | 0 |
10.1.48.C.02 | 10.1.48.C.02 Each fibre cable subunit carries one classification | 0 |
10.1.48.C.03 | 10.1.48.C.03 No mixing of RESTRICTED and CONFIDENTIAL-plus in a cable | 0 |
10.1.49.C.01 | 10.1.49.C.01 Follow GCSB directions for cabling audio secure areas | 0 |
10.1.50.C.01 | 10.1.50.C.01 Different connectors per classification at shared outlets | 0 |
10.1.50.C.02 | 10.1.50.C.02 Distinct TOP SECRET connectors in mixed outlet areas | 0 |
10.1.50.C.03 | 10.1.50.C.03 Label outlets with classification and connector type | 0 |
10.1.50.C.04 | 10.1.50.C.04 Outlet labels show classification and connector type | 0 |
10.1.51.C.01 | 10.1.51.C.01 Power filters for filtered supply (cable fundamentals) | 0 |
10.2.10.C.01 | 10.2.10.C.01 Power filters in non-shared government facilities | 0 |
10.2.6.C.01 | 10.2.6.C.01 TOP SECRET cabling inspectable every five metres | 0 |
10.2.6.C.02 | 10.2.6.C.02 Cabling inspectable at five-metre intervals | 0 |
10.2.7.C.01 | 10.2.7.C.01 Partition or gap between cable groups in shared reticulation | 1 |
10.2.8.C.01 | 10.2.8.C.01 Flexible or plastic conduit from trays to outlets | 0 |
10.2.9.C.01 | 10.2.9.C.01 Inspectable gap between TOP SECRET and lower cabinets | 0 |
10.3.10.C.01 | 10.3.10.C.01 Conduit and sealant at TOP SECRET wall penetrations | 1 |
10.3.11.C.01 | 10.3.11.C.01 Dedicated power board and UPS for TOP SECRET facility | 0 |
10.3.12.C.01 | 10.3.12.C.01 Power filters in shared government facilities | 0 |
10.3.13.C.01 | 10.3.13.C.01 Visible gap separating TOP SECRET cabinets, shared facilities | 0 |
10.3.5.C.01 | 10.3.5.C.01 Fibre optic cabling in shared government facilities | 0 |
10.3.6.C.01 | 10.3.6.C.01 TOP SECRET cables fully inspectable in shared facilities | 0 |
10.3.6.C.02 | 10.3.6.C.02 Five-metre inspection intervals in shared government facilities | 0 |
10.3.7.C.01 | 10.3.7.C.01 Separate cable groups before sharing reticulation | 1 |
10.3.8.C.01 | 10.3.8.C.01 Clear plastic covers for TOP SECRET conduits and trays | 0 |
10.3.9.C.01 | 10.3.9.C.01 Flexible or plastic conduit to wall outlets, shared facilities | 0 |
10.4.10.C.01 | 10.4.10.C.01 Seal conduit at penetrations into lower classified areas | 1 |
10.4.11.C.01 | 10.4.11.C.01 Power board inside secure area with UPS to equipment | 1 |
10.4.12.C.01 | 10.4.12.C.01 Mandatory power filters in shared non-government facilities | 0 |
10.4.13.C.01 | 10.4.13.C.01 Gap or isolator between cabinets of different classification | 0 |
10.4.13.C.02 | 10.4.13.C.02 Inspectable gap or isolator between classified cabinets | 0 |
10.4.4.C.01 | 10.4.4.C.01 Fibre optic cabling mandatory in TOP SECRET areas | 0 |
10.4.4.C.02 | 10.4.4.C.02 Fibre optic cabling in shared non-government facilities | 0 |
10.4.5.C.01 | 10.4.5.C.01 Full-length inspection of TOP SECRET cables, non-government | 0 |
10.4.5.C.02 | 10.4.5.C.02 Five-metre inspection intervals, shared non-government facilities | 0 |
10.4.6.C.01 | 10.4.6.C.01 Partition or gap for TOP SECRET shared reticulation | 1 |
10.4.6.C.02 | 10.4.6.C.02 TOP SECRET cabling in non-shared enclosed reticulation | 0 |
10.4.6.C.03 | 10.4.6.C.03 Separation for cable groups in shared non-government reticulation | 0 |
10.4.7.C.01 | 10.4.7.C.01 Clear or sealed covers on TOP SECRET conduits | 1 |
10.4.7.C.02 | 10.4.7.C.02 Clear or sealed covers on conduits and trays | 1 |
10.4.8.C.01 | 10.4.8.C.01 No cabling in party walls | 0 |
10.4.9.C.01 | 10.4.9.C.01 GCSB endorsed tamper evident seals on removable covers | 1 |
10.4.9.C.02 | 10.4.9.C.02 Uniquely numbered seals with location register | 0 |
10.4.9.C.03 | 10.4.9.C.03 Glue or sealant on TOP SECRET conduit joints | 0 |
10.4.9.C.04 | 10.4.9.C.04 Seal conduit joints with glue or sealant | 0 |
10.5.10.C.01 | 10.5.10.C.01 Minimum cable register fields at CONFIDENTIAL and above | 1 |
10.5.10.C.02 | 10.5.10.C.02 Minimum cable register content | 1 |
10.5.11.C.01 | 10.5.11.C.01 Inspect cables against register at SSP frequency | 0 |
10.5.4.C.01 | 10.5.4.C.01 Conduit label colours by classification | 1 |
10.5.5.C.01 | 10.5.5.C.01 Discreet conduit labels in public or visitor areas | 0 |
10.5.6.C.01 | 10.5.6.C.01 Wall outlet boxes show classification and numbers | 0 |
10.5.6.C.02 | 10.5.6.C.02 Outlet boxes marked with classification, cable, outlet numbers | 0 |
10.5.7.C.01 | 10.5.7.C.01 SOPs record labelling and registration conventions | 0 |
10.5.8.C.01 | 10.5.8.C.01 Label both cable ends for identification at CONFIDENTIAL-plus | 0 |
10.5.8.C.02 | 10.5.8.C.02 Label cable ends for identification and inspection | 0 |
10.5.9.C.01 | 10.5.9.C.01 Maintain a cable register at CONFIDENTIAL and above | 0 |
10.5.9.C.02 | 10.5.9.C.02 Keep a register of cables | 0 |
10.6.22.C.01 | 10.6.22.C.01 Only approved cable groups terminate on a patch panel | 0 |
10.6.22.C.02 | 10.6.22.C.02 Separate and bundle RED and BLACK cables | 0 |
10.6.23.C.01 | 10.6.23.C.01 Distinct connectors per classification in multi-classification areas | 0 |
10.6.23.C.02 | 10.6.23.C.02 Document connector type choice per classification | 0 |
10.6.23.C.03 | 10.6.23.C.03 Different connectors for each system in mixed areas | 0 |
10.6.23.C.04 | 10.6.23.C.04 Document connector types in mixed classification areas | 0 |
10.6.24.C.01 | 10.6.24.C.01 Separate cabinets for patch panels of different classification | 0 |
10.6.24.C.02 | 10.6.24.C.02 Conditions for mixed classification patch panels in one cabinet | 1 |
10.6.25.C.01 | 10.6.25.C.01 Cabinet layout RED top, BLACK centre, power bottom | 0 |
10.6.26.C.01 | 10.6.26.C.01 Record equipment layouts on rack diagrams | 0 |
10.6.27.C.01 | 10.6.27.C.01 Fibre fly lead length and long-lead conditions | 1 |
10.6.28.C.01 | 10.6.28.C.01 Equipotential bonding of all earthing points | 0 |
10.6.28.C.02 | 10.6.28.C.02 Earth bond all conductive cabinet and rack elements | 0 |
10.6.29.C.01 | 10.6.29.C.01 Cabinet rail installation for cable management | 0 |
10.6.30.C.01 | 10.6.30.C.01 Apply cable labelling principles and specific requirements | 1 |
10.6.31.C.01 | 10.6.31.C.01 Follow good practice for power cable installation | 1 |
10.7.6.C.01 | 10.7.6.C.01 Emanation threat assessment for co-located RF transmitters | 1 |
10.7.6.C.02 | 10.7.6.C.02 RF transmitters co-located with CONFIDENTIAL-plus systems | 1 |
10.7.7.C.01 | 10.7.7.C.01 Emanation threat assessment for overseas classified deployments | 1 |
10.7.7.C.02 | 10.7.7.C.02 Emanation advice for overseas system deployments | 1 |
10.7.8.C.01 | 10.7.8.C.01 Early emanation security threat assessment in projects | 0 |
10.7.9.C.01 | 10.7.9.C.01 EMI/EMC standards for equipment in secure areas | 1 |
10.8.34.C.01 | 10.8.34.C.01 Documented risk assessment before network architecture design | 0 |
10.8.34.C.02 | 10.8.34.C.02 Separation, segregation and classification in network risk assessment | 0 |
10.8.35.C.01 | 10.8.35.C.01 Security architecture applies separation and segregation | 0 |
10.8.36.C.01 | 10.8.36.C.01 Identify classification and restrictions per network part | 0 |
10.8.37.C.01 | 10.8.37.C.01 Visually distinguish systems of different classifications | 0 |
10.8.38.C.01 | 10.8.38.C.01 Maintain a network information repository | 0 |
11.1.15.C.01 | 11.1.15.C.01 Bluetooth usage policy defining permitted and prohibited use | 0 |
11.1.15.C.02 | 11.1.15.C.02 Bluetooth policy specifies security controls and verification methods | 0 |
11.1.16.C.01 | 11.1.16.C.01 Bluetooth pairing restricted to authorised devices | 1 |
11.1.16.C.02 | 11.1.16.C.02 Bluetooth discoverability disabled except during pairing | 0 |
11.1.16.C.03 | 11.1.16.C.03 Bluetooth pairing performed only in access-controlled locations | 0 |
11.1.16.C.04 | 11.1.16.C.04 Removal of Bluetooth pairings no longer needed | 0 |
11.1.17.C.01 | 11.1.17.C.01 Most secure Bluetooth configuration supported by paired devices | 0 |
11.1.17.C.02 | 11.1.17.C.02 Identify Bluetooth type, version and security capabilities for risk decisions | 0 |
11.1.17.C.03 | 11.1.17.C.03 Explicit user authentication of new Bluetooth connections | 1 |
11.1.18.C.01 | 11.1.18.C.01 Bluetooth authentication and approved algorithms for UNCLASSIFIED and IN-CONFIDENCE | 1 |
11.1.18.C.02 | 11.1.18.C.02 Bluetooth authentication and approved algorithms for RESTRICTED and SENSITIVE | 1 |
11.1.18.C.03 | 11.1.18.C.03 Risk assessment and waiver when Bluetooth cannot meet approved encryption | 0 |
11.1.19.C.01 | 11.1.19.C.01 Technical evaluation and Accreditation Authority approval for Bluetooth in secure areas | 1 |
11.1.19.C.02 | 11.1.19.C.02 Bluetooth emanation and classification separation in secure areas | 0 |
11.1.19.C.03 | 11.1.19.C.03 Bluetooth devices barred from secure areas without authorisation | 0 |
11.2.11.C.01 | 11.2.11.C.01 RF devices kept out of classified secure areas | 0 |
11.2.11.C.02 | 11.2.11.C.02 RF devices in secure areas only with Accreditation Authority authorisation | 0 |
11.2.12.C.01 | 11.2.12.C.01 Limiting RF range beyond the agency's area of control | 1 |
11.2.13.C.01 | 11.2.13.C.01 Detection of and response to active RF devices in secure areas | 0 |
11.2.14.C.01 | 11.2.14.C.01 Wireless RF and IR pointing devices prohibited in secure areas | 1 |
11.2.15.C.01 | 11.2.15.C.01 Infrared keyboard restrictions for SECRET and CONFIDENTIAL areas | 0 |
11.2.15.C.02 | 11.2.15.C.02 Infrared keyboard restrictions for TOP SECRET areas | 0 |
11.2.15.C.03 | 11.2.15.C.03 IR receiver positioned away from secure area boundary | 0 |
11.3.10.C.01 | 11.3.10.C.01 Cordless telephones not combined with secure telephony devices | 0 |
11.3.11.C.01 | 11.3.11.C.01 Speakerphone controls on secure telephone systems in secure areas | 1 |
11.3.12.C.01 | 11.3.12.C.01 Off-hook audio protection on non-accredited telephones in classified areas | 1 |
11.3.12.C.02 | 11.3.12.C.02 Push-to-talk for off-hook audio protection with clear labelling | 0 |
11.3.12.C.03 | 11.3.12.C.03 Off-hook audio protection recommended at all classifications | 1 |
11.3.13.C.01 | 11.3.13.C.01 Removal of unused voice mailboxes | 0 |
11.3.13.C.02 | 11.3.13.C.02 Voicemail expiry per electronic records retention policy | 0 |
11.3.13.C.03 | 11.3.13.C.03 Retention and disposal policy for voicemail, email and electronic records | 0 |
11.3.5.C.01 | 11.3.5.C.01 Policy governing telephone and telephone system use | 0 |
11.3.6.C.01 | 11.3.6.C.01 Personnel told maximum classification for telephone conversations | 0 |
11.3.6.C.02 | 11.3.6.C.02 Awareness of audio security risk from telephones | 0 |
11.3.7.C.01 | 11.3.7.C.01 Telephones showing the classification of the connection | 1 |
11.3.8.C.01 | 11.3.8.C.01 Accredited and encrypted telephone systems for classified traffic | 1 |
11.3.9.C.01 | 11.3.9.C.01 Cordless telephones prohibited for classified conversations | 0 |
11.3.9.C.02 | 11.3.9.C.02 Avoid cordless telephones for classified or sensitive calls | 0 |
11.4.10.C.01 | 11.4.10.C.01 Personnel told maximum classification for mobile device conversations | 0 |
11.4.10.C.02 | 11.4.10.C.02 Awareness of known mobile device risks near classified conversations | 0 |
11.4.11.C.01 | 11.4.11.C.01 Certified networks, encryption and user awareness for classified mobile use | 1 |
11.4.12.C.01 | 11.4.12.C.01 Mobile devices excluded from classified secure areas | 0 |
11.4.12.C.02 | 11.4.12.C.02 Lockers for mobile devices outside secure areas | 0 |
11.4.9.C.01 | 11.4.9.C.01 Mobile device usage policy | 0 |
11.5.13.C.01 | 11.5.13.C.01 Personal wearable device usage policy including fitness devices | 0 |
11.5.14.C.01 | 11.5.14.C.01 Personnel told maximum classification where wearables are present | 0 |
11.5.14.C.02 | 11.5.14.C.02 Awareness of wearable device risks in secure and classified areas | 0 |
11.5.15.C.01 | 11.5.15.C.01 Personal wearable devices excluded from secure areas | 0 |
11.5.15.C.02 | 11.5.15.C.02 Lockers for wearable devices outside secure areas | 0 |
11.5.16.C.01 | 11.5.16.C.01 Prohibited capabilities on medically approved wearables | 1 |
11.5.16.C.02 | 11.5.16.C.02 Accredited networks and user awareness for medically exempt wearables | 0 |
11.5.16.C.03 | 11.5.16.C.03 Privacy legislation compliance for medically permitted wearables | 1 |
11.6.59.C.01 | 11.6.59.C.01 Documented risk assessment before adopting RFID | 0 |
11.6.59.C.02 | 11.6.59.C.02 RFID risk assessment underpins security architecture | 0 |
11.6.60.C.01 | 11.6.60.C.01 Security architecture protecting RFID databases and systems | 0 |
11.6.60.C.02 | 11.6.60.C.02 Minimise data on RFID tags and subsystems | 0 |
11.6.60.C.03 | 11.6.60.C.03 Disable rewrite functions on RFID devices | 0 |
11.6.60.C.04 | 11.6.60.C.04 NZISM Chapter 11 access control requirements applied to RFID | 0 |
11.6.61.C.01 | 11.6.61.C.01 RFID usage policy developed and maintained | 0 |
11.6.61.C.02 | 11.6.61.C.02 RFID included in security policies and documentation | 0 |
11.6.62.C.01 | 11.6.62.C.01 Inspect and neutralise RFID devices on incoming items | 0 |
11.6.62.C.02 | 11.6.62.C.02 Visual inspection for attached RFID devices of concern | 0 |
11.6.62.C.03 | 11.6.62.C.03 Visual inspection for tampered RFID devices or labels | 0 |
11.6.63.C.01 | 11.6.63.C.01 RF engineering assessment for RFID in high RF or concern areas | 0 |
11.6.63.C.02 | 11.6.63.C.02 Shielding for RFID eavesdropping or radiation concerns | 0 |
11.6.64.C.01 | 11.6.64.C.01 RFID tag and reader placement to limit radiation | 0 |
11.6.65.C.01 | 11.6.65.C.01 RFID cryptography per NZISM Chapter 17 | 0 |
11.6.65.C.02 | 11.6.65.C.02 Encrypt data before writing to RFID tags | 0 |
11.6.65.C.03 | 11.6.65.C.03 RFID identifier formats that limit disclosure | 0 |
11.6.66.C.01 | 11.6.66.C.01 HMAC for RFID tag authenticity | 0 |
11.6.67.C.01 | 11.6.67.C.01 Passwords set for critical RFID functions | 0 |
11.6.67.C.02 | 11.6.67.C.02 RFID password management per NZISM Chapter 16 | 0 |
11.6.68.C.01 | 11.6.68.C.01 Temporary deactivation of long-inactive RFID tags | 0 |
11.6.69.C.01 | 11.6.69.C.01 RFID incident identification and management processes | 1 |
11.6.70.C.01 | 11.6.70.C.01 Secure disposal procedures in RFID usage policy | 0 |
11.6.71.C.01 | 11.6.71.C.01 RFID user awareness and training programme | 0 |
11.6.72.C.01 | 11.6.72.C.01 Class 3, 4 and 5 RFID tags banned from secure spaces | 0 |
11.6.72.C.02 | 11.6.72.C.02 RFID readers banned from secure spaces | 0 |
11.6.72.C.03 | 11.6.72.C.03 Class 2 RFID tags kept out of secure spaces | 0 |
11.7.29.C.01 | 11.7.29.C.01 Documented risk assessment before adopting RFID access cards | 0 |
11.7.29.C.02 | 11.7.29.C.02 Access card risk assessment underpins security architecture | 0 |
11.7.30.C.01 | 11.7.30.C.01 Security architecture protecting access card databases and systems | 0 |
11.7.30.C.02 | 11.7.30.C.02 NZISM access and cryptographic controls on access card systems | 0 |
11.7.30.C.03 | 11.7.30.C.03 Network design elements for isolating access card systems | 1 |
11.7.31.C.01 | 11.7.31.C.01 Access card usage policy developed and maintained | 0 |
11.7.31.C.02 | 11.7.31.C.02 Access cards included in security policies and documentation | 0 |
11.7.32.C.01 | 11.7.32.C.01 Tamper-resistant access card systems selected | 0 |
11.7.32.C.02 | 11.7.32.C.02 Controls reducing access card tampering risk | 0 |
11.7.32.C.03 | 11.7.32.C.03 Access card tag and reader placement to limit radiation | 0 |
11.7.32.C.04 | 11.7.32.C.04 Additional physical controls chosen per the PSR | 0 |
11.7.33.C.01 | 11.7.33.C.01 Access card cryptography per NZISM Chapter 17 | 0 |
11.7.33.C.02 | 11.7.33.C.02 Encrypt data before writing to access cards | 0 |
11.7.33.C.03 | 11.7.33.C.03 Secure Access Modules in card systems | 0 |
11.7.34.C.01 | 11.7.34.C.01 Access card incident identification and management processes | 1 |
11.7.35.C.01 | 11.7.35.C.01 Secure disposal procedures in access card usage policy | 1 |
11.8.10.C.01 | 11.8.10.C.01 Supervised or cleared maintenance of MFDs in classified areas | 0 |
11.8.10.C.02 | 11.8.10.C.02 Disposal of removed storage, drums and chipped cartridges per Chapter 13 | 1 |
11.8.10.C.03 | 11.8.10.C.03 Toner cartridge memory chips removed and disposed per Chapter 13 | 1 |
11.8.10.C.04 | 11.8.10.C.04 Supervised or cleared MFD maintenance at all classifications | 0 |
11.8.10.C.05 | 11.8.10.C.05 Recommended Chapter 13 disposal of removed MFD components | 1 |
11.8.11.C.01 | 11.8.11.C.01 Supervised or cleared use of MFD USB capability | 0 |
11.8.11.C.02 | 11.8.11.C.02 Recommended supervision of MFD USB use at all classifications | 0 |
11.8.12.C.01 | 11.8.12.C.01 Decommissioning MFD components holding data per Chapter 13 | 1 |
11.8.12.C.02 | 11.8.12.C.02 Recommended Chapter 13 disposal of data-bearing MFD components | 1 |
11.8.13.C.01 | 11.8.13.C.01 Central logging of MFD printing, scanning and copying | 0 |
11.8.3.C.01 | 11.8.3.C.01 Policy for MFDs, network printers and fax machines | 0 |
11.8.4.C.01 | 11.8.4.C.01 Encryption of classified fax messages over unsecured networks | 1 |
11.8.4.C.02 | 11.8.4.C.02 Separate devices for classified and RESTRICTED-or-lower fax traffic | 0 |
11.8.5.C.01 | 11.8.5.C.01 Sender arrangements for fax collection and non-arrival notice | 0 |
11.8.6.C.01 | 11.8.6.C.01 No direct MFD to telephone network connection below network classification | 1 |
11.8.6.C.02 | 11.8.6.C.02 Avoid direct MFD telephone connections at all classifications | 1 |
11.8.7.C.01 | 11.8.7.C.01 Identification, authentication, audit and gateway filtering for networked MFDs | 1 |
11.8.8.C.01 | 11.8.8.C.01 Networked MFDs not used for documents above network classification | 0 |
11.8.9.C.01 | 11.8.9.C.01 MFDs and fax machines placed where use is observable | 0 |
12.1.30.C.01 | 12.1.30.C.01 Mandatory preference order for evaluated products | 1 |
12.1.30.C.02 | 12.1.30.C.02 Justify and accept risk for in-evaluation products | 0 |
12.1.30.C.03 | 12.1.30.C.03 Preferred ranking when selecting evaluated products | 1 |
12.1.31.C.01 | 12.1.31.C.01 Evaluated scope must cover required security functions | 0 |
12.1.32.C.01 | 12.1.32.C.01 Check consumer guides for product requirements | 0 |
12.1.32.C.02 | 12.1.32.C.02 Comply with consumer guide product requirements | 0 |
12.1.32.C.03 | 12.1.32.C.03 Consult GCSB before buying high assurance products | 0 |
12.1.33.C.01 | 12.1.33.C.01 Verify integrity and test non-evaluated software | 1 |
12.1.34.C.01 | 12.1.34.C.01 Follow GCSB delivery procedures for high assurance products | 0 |
12.1.34.C.02 | 12.1.34.C.02 Deliver products per documented delivery procedures | 0 |
12.1.35.C.01 | 12.1.35.C.01 Check non-evaluated deliveries for tampering | 1 |
12.1.36.C.01 | 12.1.36.C.01 Leasing agreements address maintenance and sanitisation | 1 |
12.1.37.C.01 | 12.1.37.C.01 Prefer developers committed to ongoing assurance | 0 |
12.2.5.C.01 | 12.2.5.C.01 Operate high assurance products per product policy | 0 |
12.2.5.C.02 | 12.2.5.C.02 Configure evaluated products per evaluation documentation | 0 |
12.2.6.C.01 | 12.2.6.C.01 Risk assess unevaluated product configurations | 1 |
12.2.6.C.02 | 12.2.6.C.02 No unevaluated configurations for high assurance products | 0 |
12.3.4.C.01 | 12.3.4.C.01 Classify IT equipment by highest approved information | 1 |
12.3.5.C.01 | 12.3.5.C.01 Label classified-capable equipment with protective markings | 1 |
12.3.5.C.02 | 12.3.5.C.02 Label data centre equipment with asset and classification | 0 |
12.3.6.C.01 | 12.3.6.C.01 No non-essential labels on high assurance products | 0 |
12.3.7.C.01 | 12.3.7.C.01 Get GCSB authorisation before labelling HACE | 0 |
12.4.3.C.01 | 12.4.3.C.01 Monitor sources for vulnerabilities and patches | 0 |
12.4.4.C.01 | 12.4.4.C.01 Apply critical patches within two days | 0 |
12.4.4.C.02 | 12.4.4.C.02 Maintain a patch management strategy with testing | 0 |
12.4.4.C.03 | 12.4.4.C.03 No patching high assurance products without GCSB approval | 0 |
12.4.4.C.04 | 12.4.4.C.04 Apply critical patches preferably within two days | 0 |
12.4.4.C.05 | 12.4.4.C.05 Apply non-critical patches promptly | 0 |
12.4.4.C.06 | 12.4.4.C.06 Use vendor recommended patch processes | 0 |
12.4.5.C.01 | 12.4.5.C.01 Compensating controls where patches are unavailable | 1 |
12.4.6.C.01 | 12.4.6.C.01 Verify integrity and authenticity of firmware updates | 0 |
12.4.7.C.01 | 12.4.7.C.01 Assess risk of unsupported products | 0 |
12.5.3.C.01 | 12.5.3.C.01 GCSB approval before repairing high assurance products | 0 |
12.5.3.C.02 | 12.5.3.C.02 On-site repair by cleared technicians | 0 |
12.5.4.C.01 | 12.5.4.C.01 Escort requirements for uncleared technicians | 1 |
12.5.4.C.02 | 12.5.4.C.02 Sanitise equipment before uncleared technician work | 0 |
12.5.4.C.03 | 12.5.4.C.03 Adequate escort to technician ratio | 0 |
12.5.4.C.04 | 12.5.4.C.04 Escort familiar with the product being repaired | 0 |
12.5.5.C.01 | 12.5.5.C.01 Protect equipment during off-site repair | 1 |
12.5.6.C.01 | 12.5.6.C.01 Off-site repairs follow destination area classification | 1 |
12.5.6.C.02 | 12.5.6.C.02 Inspect equipment returned to secure areas | 0 |
12.6.10.C.01 | 12.6.10.C.01 Redeploy or dispose of monitors per NZISM guidance | 1 |
12.6.4.C.01 | 12.6.4.C.01 Sanitise or destroy equipment before disposal | 0 |
12.6.4.C.02 | 12.6.4.C.02 Return unsanitisable NZEO equipment to New Zealand | 0 |
12.6.5.C.01 | 12.6.5.C.01 Documented IT equipment disposal process | 0 |
12.6.5.C.02 | 12.6.5.C.02 GCSB requirements for high assurance product disposal | 0 |
12.6.5.C.03 | 12.6.5.C.03 GCSB requirements for HACE disposal | 0 |
12.6.5.C.04 | 12.6.5.C.04 GCSB requirements for TEMPEST or non-functional equipment disposal | 0 |
12.6.5.C.05 | 12.6.5.C.05 Sanitise and authorise disposal to public domain | 0 |
12.6.6.C.01 | 12.6.6.C.01 Print three random-text pages to sanitise drums | 1 |
12.6.6.C.02 | 12.6.6.C.02 Sanitise printer and copier drums before disposal | 1 |
12.6.7.C.01 | 12.6.7.C.01 Destroy drums that cannot be sanitised | 0 |
12.6.7.C.02 | 12.6.7.C.02 Destroy unsanitisable printer cartridges and drums | 0 |
12.6.8.C.01 | 12.6.8.C.01 Inspect screens for burn-in before disposal | 1 |
12.6.9.C.01 | 12.6.9.C.01 Sanitise or destroy screens with burn-in | 1 |
12.7.14.C.01 | 12.7.14.C.01 Include supply chain risk in enterprise risk management | 0 |
12.7.14.C.02 | 12.7.14.C.02 Continuously monitor supply chain risks | 0 |
12.7.14.C.03 | 12.7.14.C.03 Follow the Government Rules of Procurement | 0 |
12.7.15.C.01 | 12.7.15.C.01 Tenderers disclose export restrictions and supply chain compliance | 1 |
12.7.15.C.02 | 12.7.15.C.02 Assess contractor ability to protect information | 0 |
12.7.16.C.01 | 12.7.16.C.01 Contractual safeguarding obligations for all contractors | 1 |
12.7.16.C.02 | 12.7.16.C.02 Include information safeguarding in contracts | 0 |
12.7.16.C.03 | 12.7.16.C.03 Reject unreliable or previously breaching contractors | 1 |
12.7.17.C.01 | 12.7.17.C.01 Supply chain changes preserve continuity of supply | 0 |
12.7.18.C.01 | 12.7.18.C.01 Suppliers must provide product provenance | 0 |
12.7.18.C.02 | 12.7.18.C.02 Request provenance of products and equipment | 0 |
12.7.19.C.01 | 12.7.19.C.01 Validate equipment security against requirements | 0 |
12.7.19.C.02 | 12.7.19.C.02 Mitigate identified security deficiencies | 0 |
12.7.20.C.01 | 12.7.20.C.01 Consult GCSB on pre-installation security testing | 0 |
12.7.20.C.02 | 12.7.20.C.02 Inspect equipment on receipt for tampering | 0 |
12.7.20.C.03 | 12.7.20.C.03 Inspect and test operation before installation | 0 |
12.7.20.C.04 | 12.7.20.C.04 Verify installation before operational use | 0 |
12.7.20.C.05 | 12.7.20.C.05 Malware check code needed by equipment | 1 |
12.7.21.C.01 | 12.7.21.C.01 Secure long-term servicing for critical equipment | 1 |
13.1.10.C.01 | 13.1.10.C.01 Proportionate risk assessment before migration or decommissioning | 1 |
13.1.10.C.02 | 13.1.10.C.02 Required elements of the migration risk assessment | 1 |
13.1.10.C.03 | 13.1.10.C.03 Consider a Privacy Impact Assessment for migration | 0 |
13.1.10.C.04 | 13.1.10.C.04 Identify and terminate related service and legal agreements | 0 |
13.1.11.C.01 | 13.1.11.C.01 Contents of the system decommissioning plan | 1 |
13.1.12.C.01 | 13.1.12.C.01 Identify retention policies and laws before archiving | 0 |
13.1.12.C.02 | 13.1.12.C.02 Archive adequate system documentation on decommissioning | 0 |
13.1.12.C.03 | 13.1.12.C.03 Archive software and data needed for recovery | 0 |
13.1.13.C.01 | 13.1.13.C.01 Accreditation Authority confirms IA compliance at decommissioning | 0 |
13.1.13.C.02 | 13.1.13.C.02 Accreditation Authority confirms secure media disposal | 0 |
13.1.13.C.03 | 13.1.13.C.03 Accreditation Authority confirms asset register updates | 0 |
13.1.13.C.04 | 13.1.13.C.04 Issue a Security Decommissioning Compliance Certificate | 0 |
13.1.14.C.01 | 13.1.14.C.01 Conduct a post-decommissioning review | 0 |
13.1.9.C.01 | 13.1.9.C.01 Policy for secure end-of-life system decommissioning | 1 |
13.2.10.C.01 | 13.2.10.C.01 Conditions for reclassifying media downward | 1 |
13.2.11.C.01 | 13.2.11.C.01 Triggers for reclassifying media to a higher level | 0 |
13.2.12.C.01 | 13.2.12.C.01 Label classified media with maximum classification and endorsements | 0 |
13.2.12.C.02 | 13.2.12.C.02 Classified media classification visually identifiable | 0 |
13.2.12.C.03 | 13.2.12.C.03 Document and train on non-textual media marking schemes | 0 |
13.2.12.C.04 | 13.2.12.C.04 Label all media with classification and endorsements | 0 |
13.2.13.C.01 | 13.2.13.C.01 Warning notice on sanitised and reclassified media | 1 |
13.2.14.C.01 | 13.2.14.C.01 Register classified media with unique identifiers | 0 |
13.2.14.C.02 | 13.2.14.C.02 Register all media with unique identifiers | 0 |
13.2.6.C.01 | 13.2.6.C.01 Documented media reclassification and declassification procedures | 0 |
13.2.7.C.01 | 13.2.7.C.01 Classify media at highest stored data classification | 0 |
13.2.8.C.01 | 13.2.8.C.01 Media connected to higher systems takes the higher classification | 0 |
13.2.9.C.01 | 13.2.9.C.01 Conditions for classifying media below its connected system | 1 |
13.3.10.C.01 | 13.3.10.C.01 External-interface media in TOP SECRET areas needs approval | 0 |
13.3.4.C.01 | 13.3.4.C.01 No classified media on lower-classified systems | 0 |
13.3.5.C.01 | 13.3.5.C.01 Media storage meets PSR physical requirements | 1 |
13.3.6.C.01 | 13.3.6.C.01 Disable autorun for connectable devices and media | 0 |
13.3.6.C.02 | 13.3.6.C.02 Block unauthorised media from connecting to systems | 1 |
13.3.6.C.03 | 13.3.6.C.03 Prevent unintended writes to connected writable media | 0 |
13.3.7.C.01 | 13.3.7.C.01 Disable FireWire interfaces on classified systems | 0 |
13.3.7.C.02 | 13.3.7.C.02 Disable FireWire interfaces on all systems | 0 |
13.3.8.C.01 | 13.3.8.C.01 Media transfer processes meet PSR transfer requirements | 0 |
13.3.8.C.02 | 13.3.8.C.02 Encrypt media data before transfer to another location | 0 |
13.3.9.C.01 | 13.3.9.C.01 Log cross-classification data transfers | 0 |
13.3.9.C.02 | 13.3.9.C.02 Avoid rewriteable media for manual cross-domain transfers | 0 |
13.4.10.C.01 | 13.4.10.C.01 Destroy media types that cannot be sanitised | 1 |
13.4.11.C.01 | 13.4.11.C.01 Method for sanitising volatile media | 1 |
13.4.12.C.01 | 13.4.12.C.01 Post-sanitisation classification of volatile media | 1 |
13.4.13.C.01 | 13.4.13.C.01 Overwrite passes for non-volatile magnetic media | 1 |
13.4.13.C.02 | 13.4.13.C.02 Boot from separate media when sanitising | 0 |
13.4.13.C.03 | 13.4.13.C.03 Reset HPA and DCO before overwriting disks | 0 |
13.4.13.C.04 | 13.4.13.C.04 Attempt to overwrite the growth defects table | 0 |
13.4.13.C.05 | 13.4.13.C.05 Prefer ATA Secure Erase over block overwriting | 0 |
13.4.14.C.01 | 13.4.14.C.01 Post-sanitisation classification of magnetic media | 1 |
13.4.15.C.01 | 13.4.15.C.01 Sanitising EPROM media | 1 |
13.4.16.C.01 | 13.4.16.C.01 Sanitising EEPROM media | 0 |
13.4.17.C.01 | 13.4.17.C.01 Post-sanitisation classification of EPROM and EEPROM | 1 |
13.4.18.C.01 | 13.4.18.C.01 Sanitising flash memory media | 0 |
13.4.19.C.01 | 13.4.19.C.01 Post-sanitisation classification of flash memory | 1 |
13.4.19.C.02 | 13.4.19.C.02 Destroy items without known sanitisation procedures | 0 |
13.4.20.C.01 | 13.4.20.C.01 Destroy solid state drives before disposal | 0 |
13.4.20.C.02 | 13.4.20.C.02 ATA Secure Erase SSDs before redeployment | 0 |
13.4.20.C.03 | 13.4.20.C.03 No redeploying classified SSDs to lower environments | 0 |
13.4.21.C.01 | 13.4.21.C.01 Treat hybrid drives as solid state drives | 0 |
13.4.22.C.01 | 13.4.22.C.01 Sanitise before reuse at same or higher classification | 0 |
13.4.23.C.01 | 13.4.23.C.01 Verify sanitisation with a different product | 0 |
13.4.9.C.01 | 13.4.9.C.01 Documented media and IT equipment sanitisation procedures | 0 |
13.5.22.C.01 | 13.5.22.C.01 Documented media and IT equipment destruction procedures | 0 |
13.5.23.C.01 | 13.5.23.C.01 Approved destruction methods by media type | 1 |
13.5.24.C.01 | 13.5.24.C.01 Use approved destruction equipment, facilities and methods | 0 |
13.5.24.C.02 | 13.5.24.C.02 Use an approved facility when lacking own equipment | 0 |
13.5.24.C.03 | 13.5.24.C.03 Non-approved facilities need WEEE-rated incineration and licensed operator | 1 |
13.5.24.C.04 | 13.5.24.C.04 Safe WEEE handling at non-approved facilities | 0 |
13.5.25.C.01 | 13.5.25.C.01 Treatment of destruction waste by particle size | 1 |
13.5.26.C.01 | 13.5.26.C.01 Degausser field strength matches media coercivity | 0 |
13.5.26.C.02 | 13.5.26.C.02 Degausser evaluated for media magnetic orientation | 0 |
13.5.26.C.03 | 13.5.26.C.03 Follow manufacturer and GCSB degausser directions | 0 |
13.5.27.C.01 | 13.5.27.C.01 Cleared supervisor for media destruction | 0 |
13.5.27.C.02 | 13.5.27.C.02 Duties of personnel supervising destruction | 0 |
13.5.27.C.03 | 13.5.27.C.03 Destruction Register contents | 1 |
13.5.28.C.01 | 13.5.28.C.01 Two cleared supervisors for accountable material destruction | 0 |
13.5.28.C.02 | 13.5.28.C.02 Duties when supervising accountable material destruction | 1 |
13.5.29.C.01 | 13.5.29.C.01 No outsourcing supervision of TOP SECRET or NZEO destruction | 1 |
13.5.29.C.02 | 13.5.29.C.02 Outsourced destruction uses approved commercial facility | 0 |
13.5.30.C.01 | 13.5.30.C.01 Sanitise before transport to offsite destruction | 0 |
13.6.10.C.01 | 13.6.10.C.01 NZEO media sanitised then redeployed or destroyed | 0 |
13.6.10.C.02 | 13.6.10.C.02 Approved destruction facility for NZEO disposal | 0 |
13.6.10.C.03 | 13.6.10.C.03 NZEO media never e-recycled or sold | 0 |
13.6.11.C.01 | 13.6.11.C.01 Agency-run destruction facilities need Director-General GCSB approval | 0 |
13.6.12.C.01 | 13.6.12.C.01 Use approved secure destruction facility for media | 0 |
13.6.6.C.01 | 13.6.6.C.01 Declassify media before public-domain disposal | 0 |
13.6.6.C.02 | 13.6.6.C.02 Destroy items that cannot be sanitised or declassified | 0 |
13.6.7.C.01 | 13.6.7.C.01 Documented media and IT equipment disposal procedures | 0 |
13.6.8.C.01 | 13.6.8.C.01 Conditions for declassifying media | 1 |
13.6.9.C.01 | 13.6.9.C.01 Dispose of media without revealing prior classification | 0 |
14.1.10.C.01 | 14.1.10.C.01 Remove default accounts and passwords on classified SOEs | 1 |
14.1.10.C.02 | 14.1.10.C.02 Remove default accounts and passwords on all SOEs | 0 |
14.1.11.C.01 | 14.1.11.C.01 Separate high-risk servers exposed to public networks | 1 |
14.1.12.C.01 | 14.1.12.C.01 Characterise critical and high-risk servers | 1 |