MDS2-Audit-Logging-AUDT-Integrity-IGAU-Cybersecurity-Risk-CYBR-Monitoring | MDS2 Audit Controls + AUDT + Integrity + IGAU + Cybersecurity Risk + CYBR + Continuous Monitoring | 91 |
MDS2-Device-Identification-Inventory-MGMT-Configuration-Asset-Management | MDS2 Device Identification + MGMT + Configuration + Asset Management + HDO Inventory | 0 |
MDS2-Malware-Detection-MLDP-System-Hardening-SAHD-Cybersecurity-Upgrades-CSUP-Patch-Management | MDS2 Malware Detection + MLDP + System Hardening + SAHD + Cybersecurity Upgrades + CSUP + Patch Management | 0 |
MDS2-PHI-Data-Handling-DATA-Storage-STCF-Transmission-TXCF-TXIG-Encryption-FIPS | MDS2 PHI Handling + DATA + STCF Storage + TXCF Transmission + TXIG Integrity + Encryption + FIPS | 90 |
MDS2-Person-Node-Authentication-Authorization-Auto-Logoff-AUTH-PAUT-NAUT | MDS2 Authentication + Authorization + Auto Logoff + PAUT + NAUT + AUTH + Identity Management | 76 |
MDS2-Physical-Security-PLOK-Workstation-Disposal-Backup-DTBK-Disaster-Recovery | MDS2 Physical Security + PLOK + Workstation + Disposal + Backup + DTBK + Disaster Recovery | 47 |
MDS2-Roadmap-Third-Party-RDMP-Security-Guidance-SGUD-SBOM-Vulnerability-Disclosure-Programme | MDS2 Roadmap + RDMP + Third Party + Security Guidance + SGUD + SBOM + Vulnerability Disclosure + Coordinated | 14 |
MDS2-Scope-NEMA-HN-1-2019-HIMSS-AAMI-Manufacturer-Disclosure-FDA-Section-524B-Procurement-Voluntary | MDS2 Scope + NEMA HN 1-2019 + HIMSS + AAMI + FDA Section 524B + Procurement + Voluntary Industry Standard | 0 |
2.3.1 | 2.3.1 Complete every question of the form with Yes, No or N/A, and explain through notes | 0 |
ALOF | ALOF Automatic logoff: disclose re-authentication after inactivity and whether the timeout is configurable | 0 |
AUDT | AUDT Audit controls: disclose what the device logs, how logs are timed, exported, protected and reviewed | 0 |
AUTH | AUTH Authorization: disclose how the device blocks unauthorised users and manages privileges | 0 |
CHANGES | Sections 4 and 5: changes from HN 1-2013 and the worksheet | 0 |
CONN | CONN Connectivity capabilities: disclose every wireless, physical and network connection, protocol, API and internet dependency | 0 |
CSUP | CSUP Cybersecurity product upgrades: disclose who can patch each software component, how, and how updates are assessed and announced | 0 |
DEFS | 1.3 Definitions | 0 |
DIDT | DIDT Health data de-identification: disclose the device's built-in de-identification and the standard it follows | 0 |
DOC | DOC Device description: identify the device, its networked use, vulnerability disclosure, ISAO membership, diagrams and SaMD status | 0 |
DTBK | DTBK Data backup and disaster recovery: disclose where data lives long-term and how data, configuration and software are backed up and restored | 0 |
EMRG | EMRG Emergency access: disclose any break-glass access to PII in a medical emergency | 0 |
HDO-USE | 2.1 and 2.2 Obtaining and using the form (healthcare delivery organisations) | 0 |
IGAU | IGAU Health data integrity and authenticity: disclose integrity checks and fault protection for stored health data | 0 |
MAPPING | Section 3: comparison with IEC TR 80001-2-2, ISO/IEC 27002:2013 and NIST SP 800-53 Rev. 4 | 0 |
MLDP | MLDP Malware detection and protection: disclose anti-malware support, its limits, compensating controls, allow-listing and host intrusion detection | 0 |
MPII | MPII Management of personally identifiable information: disclose what PII the device holds and every path by which it moves | 0 |
NAUT | NAUT Node authentication: disclose mutual authentication of communicating nodes, network access control and certificate use | 0 |
OTHR | OTHR Other security considerations: disclose security risks and controls not covered elsewhere, compensating controls included | 0 |
PAUT | PAUT Person authentication: disclose unique accounts, external authentication, lockout, default accounts, password rules, MFA, SSO and credential storage | 0 |
PLOK | PLOK Physical locks: disclose whether PII-bearing components and removable media are physically secured | 0 |
RDMP | RDMP Roadmap for third-party components in the device life cycle: disclose secure development, supplier evaluation, support dates and end-of-life planning | 0 |
RMOT | RMOT Remote service: disclose remote service connections, who initiates them, session indication, patient data visibility and other remote functions | 0 |
SAHD | SAHD System and application hardening: disclose hardening standards, certification, integrity checking, access control, disabled accounts, ports, services and boot protection | 0 |
SBOM | SBOM Software bill of materials: disclose whether an SBOM exists, its format and fields, how to list installed components and how it is updated | 0 |
SGUD | SGUD Security guidance: disclose owner and operator security documentation, data sanitisation, account documentation and recommended compensating controls | 0 |
STANDARD | ANSI/NEMA HN 1-2019: the standard, its scope and the shared-responsibility model | 0 |
STATUS | Edition status and the instruments that point at MDS2 | 0 |
STCF | STCF Health data storage confidentiality: disclose encryption of stored data, its coverage and defaults, key management and database location | 0 |
TXCF | TXCF Transmission confidentiality: disclose cabling, encryption in transit, destination limits, authenticated connections and secure protocols | 0 |
TXIG | TXIG Transmission integrity: disclose protection against alteration in transit and externally cabled sub-components | 0 |