IMDRF N81 Characterization Considerations for Medical Device Software and Software-Specific Risk (2025)

51 controls. 0 other frameworks in our corpus share controls with it. Here is all of it, and how much of it you are already doing.

Page built . This page is derived from the framework corpus, which changes when the corpus is extended rather than daily.

51 controls 0 frameworks share controls with it International verified against its source document

Every control below is one this framework asks for. The right hand column counts how many other frameworks in our corpus carry the same control, which is the difference between doing this work once and doing it again for the next standard.

There is no implementation kit for this framework yet. The control list and the overlap above are free and complete.

What you already have

Frameworks whose controls overlap this one, most first. If you run any of them, the count is roughly what you have already evidenced.

No measured overlap with another framework in the corpus.

Every control

CodeControlAlso in
4.1.1-1Stating the medical purposes0
4.1.1-2Stating the intended disease or condition0
4.1.1-3Stating the intended patient populations0
4.1.1-4Stating the intended users0
4.1.1-5Stating the intended use environment0
4.1.1-6Stating contraindications0
4.1.1-7Describing function, inputs, outputs and workflow0
4.2.1-Intended-Disease-or-ConditionTarget disease or condition and its state0
4.2.1-Intended-Patient-PopulationIntended patient population boundary0
4.2.1-Medical-PurposeMedical purpose the software serves0
4.2.2-Intended-Use-EnvironmentIntended use environment and how remote it is0
4.2.2-Intended-UserIntended user of the software0
4.2.2-Role-of-Software-and-Output-Within-the-Healthcare-Task-InterventionPart played by the software output in the care task0
4.2.2-Timing-Within-Healthcare-Task-InterventionWhen the output falls within the care task0
4.2.3-Degree-of-AutonomyHow far the software acts without user control0
4.2.3-Destination-Target-of-OutputDestination or target of the output0
4.2.3-Explainability-of-Software-and-OutputHow far the software logic and output can be explained0
4.2.3-Input-SourceWhere the software inputs come from0
4.2.3-Output-TypeKind of output the software produces0
4.2.4-Degree-of-Learning-Change-Management-AutonomyAutonomy of learning and change management0
4.2.4-Domain-of-Learning-Change-ImplementationDomain or scope of learning and change0
4.2.4-Installation-Update-and-Error-Correction-InfrastructureInfrastructure for installation, updates and error correction0
5-Key-Point-1Consider direct and indirect harms0
5-Key-Point-2Hazards arising from information and loss of effectiveness0
5-Key-Point-3Harms depend on intended use0
5.1Understand the software before assessing risk0
5.1-aAsk why each characteristic matters0
5.1-bAccount for interdependencies between characteristics0
5.1-cUse the characterization questions to find hazards0
5.1-dShow whether software changes device risk0
5.2Estimate risk from likelihood and severity0
5.2-aAssess severity of direct and indirect harm0
5.2-bSet software failure likelihood to one0
5.2-cContextualize severity with the guiding questions0
5.2-dCheck for single-point software failure0
5.3Categorize early and before controls0
5.3-aAllow interdependence and unequal weighting0
APP-ASample intended use statement0
APP-BSummary table of characterization features0
APP-CQuestions for finding software hazards0
APP-DWorked examples linking features to risk0
APP-EPaired examples comparing risk considerations0
CL1Introduction and background to the guidance0
CL2.1Aim of the document0
CL2.2Scope of the document0
CL4Why medical device characterization matters0
CL4.1Purpose of the intended use statement0
CL4.2Medical device software description and characterization categories0
CL5Software risk characterization overview0
CL5.3-bRecognize jurisdictional differences0
CL6Implementation considerations for jurisdictions0

Tell me when IMDRF N81 Characterization Considerations for Medical Device Software and Software-Specific Risk (2025) files something new

One email when a public company newly discloses something this framework governs, naming the company and what our corpus says it puts in scope. Nothing else, and one click to stop.

What this page is

A control-level reference for IMDRF N81 Characterization Considerations for Medical Device Software and Software-Specific Risk (2025), drawn from our framework corpus. Control codes and titles are references to the standard, not reproductions of it. The overlap counts and the auditor artefacts are our own work and are the part you will not find elsewhere.

Measure this against what you already run · All frameworks · Today's edition