Australia and New Zealand (force where electrical safety legislation calls it up)

AS/NZS 4836:2023 Safe Working on or near Low-Voltage and Extra-Low Voltage Electrical Installations and Equipment

46 controls. 0 other frameworks in our corpus share controls with it. Here is all of it, and how much of it you are already doing.

Page built . This page is derived from the framework corpus, which changes when the corpus is extended rather than daily.

46 controls 0 frameworks share controls with it Australia and New Zealand (force where electrical safety legislation calls it up) verified against its source document

Every control below is one this framework asks for. The right hand column counts how many other frameworks in our corpus carry the same control, which is the difference between doing this work once and doing it again for the next standard.

There is no implementation kit for this framework yet. The control list and the overlap above are free and complete.

What you already have

Frameworks whose controls overlap this one, most first. If you run any of them, the count is roughly what you have already evidenced.

No measured overlap with another framework in the corpus.

Every control

CodeControlAlso in
1.1-1.41.1 to 1.4 Scope, application, normative references and definitions0
1010.1 to 10.3 Supervision of electrical work and of energized work0
1111 Personal protective equipment selection and requirements0
12.1-12.212.1 and 12.2 Medical attention and preservation of the incident scene0
12.312.3 Reporting electrical incidents and shocks0
2.1-2.22.1 and 2.2 Risk management before work: competent determination, planning and the decision not to proceed0
2.3.1-2.3.22.3.1 and 2.3.2 Identifying hazards and electrical hazards before work0
2.3.32.3.3 Identifying sources of electric shock0
2.3.42.3.4 Arc blast and arc flash risk0
2.3.52.3.5 Hazardous areas: no live work and control of ignition sources0
2.3.62.3.6 Other risk factors to identify before work0
2.3.72.3.7 Work zone: 3 m near-zone and 500 mm work-on zone0
2.42.4 Assess and prioritize risk at the work site0
2.52.5 Applying risk controls using the hierarchy of control0
2.6-2.72.6 and 2.7 Monitoring and review, and means of reducing risk0
2.82.8 Work permit systems0
3.1.1-3.1.23.1.1 and 3.1.2 Isolation principles and positive identification0
3.1.33.1.3 Isolating the electrical equipment from all supplies0
3.1.43.1.4 Securing isolation: locks, padlocks and tags0
3.1.53.1.5 Proving de-energization0
3.1.6-3.1.83.1.6 to 3.1.8 Temporary bonding, the safe work area and work on de-energized equipment0
3.23.2 Fault-finding and testing0
3.33.3 Testing plug-in electrical equipment0
4.1-4.3-info4.1, 4.3.8, 4.3.9 and 4.3.12 Specific situation factors: high voltage producing equipment, induced voltage (EMF) and lightning0
4.24.2 Safety observer duties and competence0
4.3.14.3.1 Work on or near exposed energized conductors and live conductive parts0
4.3.10-4.3.114.3.10 and 4.3.11 Material containing asbestos and equipment containing PCBs0
4.3.13-4.3.144.3.13 and 4.3.14 Cutting cables or wiring enclosures and removing out-of-service equipment0
4.3.154.3.15 Leaving work unfinished0
4.3.24.3.2 Capacitors0
4.3.3-4.3.64.3.3 to 4.3.6 Hazardous areas, trafficable areas, areas of reduced mobility and illumination0
4.3.74.3.7 Batteries and d.c. supplies0
5.1-5.25.1 and 5.2 Elevated work, overhead conductors and climbing poles or structures0
5.3-5.45.3 and 5.4 Conductive poles and structures, and erecting equipment near live conductors0
6.1-6.26.1 and 6.2 Working below ground: safe system of work and site assessment0
6.36.3 Excavating at or near cables and services0
6.4-6.56.4 and 6.5 Identifying the cable before work0
6.6-6.76.6 and 6.7 Other excavation risks and cutting underground cables0
7.17.1 Initial energization of an electrical installation or equipment0
7.2-7.37.2 and 7.3 Re-energization and extra-low voltage testing0
8.1-8.28.1 and 8.2 Safety equipment and insulated tools0
8.38.3 Portable electric tools: RCD or isolating transformer protection0
8.4-8.58.4 and 8.5 Ladders and insulating barriers, covers and mats0
99.1 to 9.3 Test equipment selection, category rating and checks0
APPInformative Appendices A to F0
introStatus, edition and legal effect of AS/NZS 4836:20230

Tell me when AS/NZS 4836:2023 Safe Working on or near Low-Voltage and Extra-Low Voltage Electrical Installations and Equipment files something new

One email when a public company newly discloses something this framework governs, naming the company and what our corpus says it puts in scope. Nothing else, and one click to stop.

What this page is

A control-level reference for AS/NZS 4836:2023 Safe Working on or near Low-Voltage and Extra-Low Voltage Electrical Installations and Equipment, drawn from our framework corpus. Control codes and titles are references to the standard, not reproductions of it. The overlap counts and the auditor artefacts are our own work and are the part you will not find elsewhere.

Measure this against what you already run · All frameworks · Today's edition